BS 1363-1:2016 specifies standards for thirteen A fused plugs having insulating sleeves online and impartial pins, for family, advertisement and lightweight commercial reasons, with specific connection with defense in common use. The plugs are compatible for the relationship of transportable home equipment, sound-vision gear, luminaires, and so on. in a.c. circuits in basic terms, working at voltages now not exceeding 250 V r.m.s. at 50 Hz. extra specifications are incorporated for plugs compatible for electrical car charging. requisites are particular for plugs incorporating a fuse hyperlink conforming to BS 1362:1973. The plugs could be rewirable or non-rewirable whole with versatile cable. different types of plugs are particular overlaying basic and tough use. Rewirable plugs are meant to be used with versatile cables conforming to the correct components of BS EN 50525 (see Annex H), having conductor cross-sectional parts from half mm2 to 1.5 mm2 inclusive.

Show description

Read or Download 13 A Plugs, Socket-outlets and Adaptors: Specification for Rewirable and Non-rewirable 13 A Fused Plugs BS 1363 PDF

Similar nonfiction_2 books

Download e-book for iPad: CISA Review Manual 2007 by Isaca

The handbook positive factors exact descriptions of the initiatives played through IS auditors and the data required to plot, deal with and practice IS audits. the recent version additionally good points new case reports to aid a candidate's knowing of present practices. additionally integrated are definitions of phrases most ordinarily came upon at the examination, perform questions related in content material to what has formerly seemed at the examination and references to extra research fabrics on particular issues.

The Self (Ratio Special Issues) by Strawson Strawson PDF

This choice of philosophical papers displays at the lifestyles and nature of the self. a set of philosophical papers dedicated to the topic of the self. displays on key questions about the life and nature of the self. includes contributions from prime experts within the box: Barry Dainton, Ingmar Persson, Marya Schechtman, Galen Strawson, Bas van Fraassen, and Peter van Inwagen.

Extra info for 13 A Plugs, Socket-outlets and Adaptors: Specification for Rewirable and Non-rewirable 13 A Fused Plugs BS 1363

Example text

1 A is then passed continuously through the calibrated link for 60 min ± 5 min. At the end of this time the temperatures measured by the thermocouples are noted, the cover of the jig is then removed and the millivolt drop between the end surfaces of the end caps of the calibrated link is measured whilst it is still carrying the test current. C. shall be used for the calibration. 05 W; b) the temperature difference between the fuse contact clips does not exceed 2 °C. 1. 5 If the associated clearance is less than 3 mm, the minimum groove width may be reduced to one-third of this clearance.

C) In Clause 6, Procedure, either CTI or PTI is determined. 2 of BS 5901. 1, of BS 5901 based on the appropriate creepage distance, material group, pollution degree conditions and on the rated voltage of this standard declared by the manufacturer. c. c. up to and including V V Rated impulse withstand voltage V Overvoltage Category 230/400 300 NOTE 1 For more information concerning supply systems see BS EN 60664-1. NOTE 2 For more information concerning Overvoltage Category see BS EN 60664-1. I II III 1 500 2 500 4 000 a --`,,`-`-`,,`,,`,`,,`--- NOTE 3 Accessories fall into Overvoltage Category III.

The plug is fixed to the oscillating member of the apparatus so that when this is vertical the axis of the flexible cord at the point of entry is vertical and passes through the axis of oscillation. Samples with flat flexible cords are mounted so that the major axis of the section is parallel to the axis of oscillation. The flexible cord is loaded with a weight as given in Table 2. The distance between the point of entry to the plug and the axis of oscillation is adjusted so that the weight makes the minimum lateral movement as the oscillating member moves.